
We have identified that there was a period during which the “Contact Us” form on our website may not have been functioning properly, and inquiries may not have been successfully submitted.
Period of the issue:
After the website renewal: January 8, 2026 – January 27, 2026
We sincerely apologize for any inconvenience this may have caused to those who used our website.
The issue has now been resolved, and the “Contact Us” form is currently functioning normally.
If you submitted an inquiry during the above period and have not received a response from us, we kindly ask that you contact us again at the email address below.
We appreciate your understanding.
ChromaNik Technologies has launched SunShell Peptide C9 and SunShell Protein C8, new bio-molecule-oriented columns designed to improve separation performance and reproducibility of peptides and proteins in LC-MS analysis.
The specifications are as follows.
Particle size: 2.6 μm (core diameter: 1.6 μm)
Pore size: 16 nm
Carbon load: 2.5%
Bonded phase: Hexafunctional C18
Inertization:
Sunniest end-capping + proprietary advanced inert treatment to suppress non-specific adsorption
Feature:
Particle size: 3.4 μm (core diameter: 3.0 μm)
Pore size: 16 nm
Carbon load: 0.5%
Bonded phase: C8
Inertization:
Sunniest end-capping + proprietary advanced inert treatment to suppress non-specific adsorption
Feature:
These columns are derivative products of the SunShell Peptide C18, launched in 2024, and are manufactured using the same advanced inertization technology.
By effectively minimizing adsorption, they support LC-MS analysis across a broad range of targets, from moderately to highly hydrophobic peptides and proteins.
For full details on the SunShell Peptide C18 series lineup and pricing, please refer to the dedicated brochure [PDF].
Thank you for your continued interest.

Our website has been renewed.
Some page links may still be under adjustment; however we will addressing these issues sequentially.
If you find any issues, please feel free to let us know.
We will continue to enrich the content on our website going forward.

We are pleased to announce that new application data has been added.
Most of the data were generated using the new high-durability HPLC column SunBridge, launched in February 2025.
1220 Polysaccharides (galactan)
1219 ABEE-derivatized sugars
1218 Quercetin glycosides
1217 Coproporphyrin I
1216 Bile Acids and PFOS (a key PFAS) in SRM1958
1215 Bile Acids and PFOS (a key PFAS) in umbilical cord blood
1214 Bile Acids and PFOS (a key PFAS)
1213 Capsaicin in Chili Peppers
1212 Catechins (4)
1211 Sterols
1210 Fluorobenzene and benzene (3)
1209 Oligonucleotide(2)
In addition to the launch of the SunBridge platform, ChromaNik Technologies is pleased to announce the release of two new product lines: SunBridge C18 (1.8 µm, 3 µm) and SunBridge PFP-R (3 µm).
The SunBridge series, developed based on unique Ultra-Hybrid Technology, is an organosilica column first introduced to the market in February 2025.
The SunBridge C18 columns, available in both sub-2 µm and 3 µm particle sizes, deliver outstanding efficiency and reproducibility for high-resolution separations, making them ideally suited for both UHPLC and conventional HPLC systems.
For more details and specifications, refer to the brochure[PDF] and the poster[PDF] provided.

The SunBridge PFP-R (3 µm) column introduces enhanced selectivity for fluorinated compounds (including both short- and long-chain PFAS), aromatic isomers, and polar analytes, offering unique retention characteristics that complement traditional C18 phases.
For more details and specifications, refer to the brochure[PDF] and the PFAS poster[PDF] provided.

With these new additions, the SunBridge series further extends its versatility, enabling researchers and analysts to address a wider range of separation challenges with confidence.

We are pleased to announce that new application data has been added.
All data were generated using the new high-durability HPLC column SunBridge, launched in February 2025.
1208 Crude Drugs and Related Drugs (9) – Glycyrrhiza
1207 Crude Drugs and Related Drugs (8) – Magnolia Bark
1206 Crude Drugs and Related Drugs (7) – Citrus Unshiu Peel
1205 Crude Drugs and Related Drugs (6) – Apricot / Peach Kernel
1204 Crude Drugs and Related Drugs (5) – Scutellaria Root
1203 Crude Drugs and Related Drugs (4) – Gardenia Fruit
1202 Crude Drugs and Related Drugs (3) – Peony Root
1201 Crude Drugs and Related Drugs (2) – Cornus Fruit
1200 Tricyclic antidepressants
1199 Benzalkonium chloride
1198 Flavonoids
1197 Lysozyme (Protein)
1196 ABEE-derivatized D-glucose
1195 Nucleotides on PEEK bioinert column
1194 High-throughput analysis of Analgesics
1193 Effect of pH on ionizable compounds
1192 Basic polypeptides
1191 Metal chelating compound (Oxine)
1190 α-carotene and β-carotene
1189 DNPH derivatized aldehyde (3)
1188 Hinokitiol on PS Inert vs. SS Column
1187 p-Aminobenzoic acid and Protocatechuic acid
1186 Phenylglyoxylic Acid and hippuric acids
1185 PFAS (Per- and Polyfluoroalkyl Substances)
SunBridge C18 5 µm, featuring exceptional alkaline durability enabled by Ultra Hybrid Technology, was launched in February 2025.
Subsequently, SunBridge C18 3 µm was launched in April 2025.
SunBridge C18 3 µm is effective for improving separation performance and ensuring stable operation in oligonucleotide analysis under high-temperature and high-pH conditions.

Fig. Part of Application No. 1209: Oligonucleotide (2) using SunBridge C18 3 µm [PDF]
For more details, please visit the dedicated page.

1184 Crude Drugs and Related Drugs (1) – Pueraria Root
1183 PFAS (Per- and Polyfluoroalkyl Substances)
1182 Phenethylamines (Stimulants, Stimulant precursors, Narcotics)
1181 PFAS (Per- and Polyfluoroalkyl Substances)
1180 Vulcanization accelerator for tire rubber

ChromaNik Technologies has officially introduced its latest innovation in chromatography: the SunBridge HPLC column. Designed with cutting-edge technology, SunBridge aims to provide superior performance, improved separation efficiency, and enhanced durability under a wide range of analytical conditions.
The new column is tailored to meet the demands of modern chromatography applications, offering robust performance for challenging compounds and complex mixtures. With its advanced design, SunBridge is expected to set a new standard for HPLC.
For more details and specifications, refer to the PDF file provided.

1179 Bisphenol A and its glucuronide conjugate
1178 Nucleic acid bases (8)
1177 Angiotensin II (Peptide)
1176 Phospholipids, Lysophospholipids
1175 Amino Acids derivatized with OPA (3)
1174 Organic synthesis-related compounds
1173 Nucleic acid synthesis-related compounds
1172 Lactic acid and acetic acid
1171 Oligonucleotide
1170 Isomers of phthalic acid
1169 Phosphates on PS inert column
1168 Local anesthetic (3)
1167 Substituted methoxybenzene

We introduced the inert column hardware “PS inert,” featuring a multilayer organic inert surface treatment applied to metal surfaces, at JASIS 2023. Order acceptance has now begun.
Unlike so-called metal-free (PEEK) columns, PS inert is compatible with connections to virtually all HPLC systems. It effectively suppresses non-specific adsorption of analytes and contributes to improved detectability.
PS inert can be manufactured at an additional cost of JPY 25,000 (excluding tax) on top of the standard column price.
Available Column Dimensions:
2.1 × 50 mm, 2.1 × 100 mm, 2.1 × 150 mm,3.0 × 50 mm, 3.0 × 100 mm,
4.6 × 50 mm, 4.6 × 100 mm, 4.6 × 150 mm, and others
Compatible Packing Materials:
Our in-house manufactured HPLC packing materials, including the following stationary phases:
SunShell, Sunniest, SunArmor, and Sunrise
For more details, please visit this page.
1166 Steroids (2)
1165 Steroids (1)
1164 Sulfonamides
1163 Branched-chain amino acids (2)
1162 Glyphosate compounds
1161 Cannabidiol and δ-9-Tetrahydrocannabinol
1160 Components of explosive(2)
1159 DNPH-aldehyde (2)
SunShell 2.6 um, 5 um column tubes use IDEX Isobar column hardware. Currently, some IDEX Isobar column hardware takes more than 6 months to be delivered. For sizes that are out of stock due to late delivery, we will use domestically produced column hardware in parallel. We have confirmed that the performance of domestically produced column hardware is comparable to that of Isober column hardware.
Thank you for your understanding.

We have developed new products incorporating a novel endcapping technology (Tandem TMS treatment).
〈Prominert C18 and Biphenyl 3.5 µm Brochure〉
https://chromanik.co.jp/pdf/Prominert_cat_en.pdf
Key Features:
HPLC 2022 Poster has been released.
Please check the technical information.
Chromanik Technologies will be exhibiting at HPLC2022.
Poster presentations will be given with the following contents.
https://hplc2022.org/sponsors-exhibitors/
Poster Session – 1 Monday at 1:45 – 3:45 PM in the Exhibition Hall P-M-0100: Column Technology
P-M-112 Evaluation of Retention Behavior and Stability of a Novel Trifunctional Biphenyl Phase
Norkazu Nagae, Tomoyasu Tuskamoto,
Chromanik Technologies, Osaka, JAPAN; Scott Silver, Pyvot, New York, NY, USA
P-M-113 A Novel End-capping for Reversed Phase for LC/MS
Etusko Shearer, BioNik Inc., Fuji, JAPAN; Norikazu Nagae, Tomoyasu Tsukamoto,
Chromanik Technologies, Osaka, JAPAN
Hello!
Our distributor, Pyvot, made a video of the commentary.
Please see the link below to YouTube or the embedded video.

https://www.youtube.com/watch?v=v_KvsnRSqOQ
https://www.youtube.com/watch?v=Li2snagfpj8
https://www.youtube.com/watch?v=Fkw2c_KMIiU&t=383s
We will stop exhibiting to prevent the spread of coronavirus.
May 31 – June 4, 2020 | Short Courses May 30 – 31
George R. Brown Convention Center | Houston, Texas
We will exhibit at ASMS2020.